Raised floor for heavy-duty applications
Ligna power shoulders the weight of heavy-duty situations.
In certain circumstances floors need to withstand heavier loads, for example foyers, manufacturing plants, museums and libraries. In such situations, ligna power offers unbeatable load-bearing strength. The floor system carries immense loads.
INFORMATION
BRAND
Lindner
PRODUCT TYPE
Underfloor Heating
FIRE RESISTANCE (FIRE PROTECTION)
Fire resistance : DIN 4102-2 F 30 possible with additional measures
PRODUCTION
Made in Germany
CLASS
EN 12825 Class 1
BUILDING MATERIAL CLASS (FIRE PROTECTION)
Designation by building authorities : DIN EN 13501-1 (Difficult to ignite)
EVIDENCE GREEN LEVEL CERTIFICATE
-Circularity : Majority of components can be reused/refurbished
-Life Cycle Assessment : EPD according to ISO 14025 and EN 15804
-Cradle to Cradle Certified® : No C2C Certified® label available
COVERING
Surfacing suitability : Heavy Duty Coverings
PRODUCT.STUETZFUSSRASTER_WERT.NAME
600 mm x 600 mm
SUSTAINABILITY DECLARATIONS
-FSC : optional (TUEV-COC-000515)
-French VOC Regulation : Emission class A+
-Circular economy : Cradle to Cradle possible
-Product Self-Declaration : Self-declaration according to ISO 14021 possible
-EPD (Environmental Product Declaration) : EPD according to EN 15804 / ISO 14025 possible
BUILDING ACOUSTICS
- DIN EN ISO 717 1 : D n,f,w (59)
- DIN EN ISO 717 2 : ∆L w (29)
WEIGHT
38 - 42 kg/m²
PLATE THICKNESS
38 - 38.5 mm
EARTH RESISTANCE
≥ 1 x 106 Ω
STANDARD PEDESTAL HEIGHT
70 - 2000 mm
STATICS
- Seismic safety : Possible
- Load and deflection class : DIN EN 12825 1 6A
- Point load (breaking load) : DIN EN 12825 P breaking load 6 kN (12 kN) - 7 kN (14 kN)
ADDITIONAL EQUIPMENT
EXPANSION JOINTS PROFILES
In order to take up horizontal and vertical movements in a structural and inconspicuous manner, expansion joint profiles are used in the area of the raised access floor, adapted to the application.
REINFORCEMENT PROFILES
Standard Lindner floor systems already exhibit high load-bearing capacities. Should these still not be sufficient, the system can be upgraded by reinforcement profiles. Various options are possible, from the lightest stringer which increases lateral rigidity through to a C-profile.
AIR VENTILATION OUTLETS
Air ventilation outlets allow the room to be air-conditioned and ventilated without creating draughts. Various systems are available: -Open system Ventilation takes place directly in the cavity for installations, which is designed as a pressure floor, through the corresponding air ventilation outlets or rather through the hexagonal ventilation outlets into the room.
FACINGS
Staircases, platforms, etc. need to be finished with a front cladding (facing). Where features such as free-standing borders are required, the top edges of the facing will be protected with a stair edging profile.
CAVITY BARRIERS
Three different types of cavity barriers can be possible to meet the different requirements in the raised access floor area. -Ventilation barriers made from coated chipboard panels -Fire protection barriers made from solid gypsum wall blocks (min. 80 mm)