EFP International BV

Efp Ssg Concealed Window

SSG CONCEALED WINDOW

Efp Ssg Concealed Window

SSG CONCEALED WINDOW 

EFP 55 SSG window system is a top hung or side hung window by means of friction hinges or friction stays available in single or double glass units.

information

BRAND

EFP

PRODUCT TYPE

Window System 

CONSTRUCTION

Any instructions regarding the manufacture and installation of the system must be strictly adhered to. 

NON THERMALLY BROKEN, DOUBLE GLASS

- EFP 55 SSG
- 94mm deep frame

CLASSIFICATIONS 

-Air permeability : BS EN 12207 – Class 4
-Water tightness : BS EN 12208 – Class E 750
-Wind resistance : BS EN 13116 – 2400 Pa design – 3600 Pa safety
-2400 Pa is dependent upon correct mullion and transom selection to suit span and spacing by project.

USE 

Wall

COLLECTION

Ssg

MATERIALS 

Depending largely upon the glass specification, generally the curtain wall framing reduces the figure by 2dB(A)

DEVELOP 

The integrated curtain wall window system EFP 55 SSG, frames and vents are developed with and without thermal barrier.

Efp Ssg Concealed Window

THERMALLY BROKEN, DOUBLE GLASS 

- EFP 55 SSG, Class 1.0 for standard CW
- EFP 55 SSG, Class 2.1 for standard CW
- EFP 55 SSG, Class 2.1 for 2 an 4 sided SSG CW

PRODUCTION 

Made in The Netherlands

FRICTION STAYS AVAILABLE

Single Or Double Glass Units

TECHNICAL DRAWINGS

Efp Ssg Concealed Window
Efp 55 Ssg Tb Capped Hp
Efp Ssg Concealed Window
Efp 55 Ssg Tb
Efp Ssg Concealed Window
Efp 55 Ssg Non Tb

GLASS THICKNESS 

The system is glazed from the outside, structurally bonded to the moving frame (window vent). Glass should conform the requirements of BS 6262 for thickness and type, in terms of wind resistance, safety and security

DRAINAGE 

The system is pressure equalised, drained, achieved by meeting the requirements of “ventilated and drained glazing system” as specified in BS 6262

EXPOSURE CATEGORY

The system will achieve the following criteria when manufactured, installed and glazed to EFP recommended procedures.

THERMAL INSULATION 

Classification in accordance with DIN 4108 or EN ISO 10077-1 Thermally broken window: The thermal transmittance ( Uf ) W/m2 K, is depending on the insulator strip, calculated as per EN ISO 10077-1. Comparable with class 1.0 or 2.1 DIN 4108-4 Table 3

CONSTRUCTION 

The system is constructed from extruded aluminium profiles, using alloy 6063 complying the requirements of BS 1474. The thermal barrier system is achieved by means of PA Glass fiber reinforced extrusion.

PERFORMANCE

Glazing vision strips are made of EPDM conforming to BS 4255 Part 1

SIZE LIMITATIONS 

The size limitation of the system depends mainly on the hardware used