Isometal Isowall Wall Panels
ISOWALL WALL PANELS
INFORMATION
THICKNESSES (S)
mm 30 - 40 - 50 - 80 - 100 - 120 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities (max. mm 200).
BRAND
Isometal
PRODUCT TYPE
Wall panels
PROTECTIVE TREATMENTS FOR EXTERNAL SUPPORT AVAILABLE
On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films.
SUPPORTS
galvanized steel, galvanized prepainted or plastified steel; stainless steel; natural or prepainted aluminium; copper (CORAM).
INSULATION THROUGH CONTINUOUS FOAMING PROCESS
Polyurethane resins (PUR) and (not standard) polyisocianurate foams (PIR), density 39 ±2 Kg/m³ Declared value of thermal transmittance for a panel after 25 years of its installation, (Appendix C - EN 13165) Initial value of thermal conductivity: λ = 0.020 W/(mK)
EPD CERTIFICATION (CAM)
CAM available only in PIR version.
For more information on CAM certification, contact the technical / commercial department.
FOAM INSULATION IN CONTINUOUS OF
polyurethane resins (PUR) or (PIR to request, non-standard). Density at the heart PUR: 39 ± 2 kg / m³ Declared value of thermal transmittance for a panel after 25 years of its installation, (Appendix C - EN 13165) - Initial value of thermal conductivity: λ = 0.020 W/(mK)
PROTECTIVE TREATMENTS FOR EXTERNAL SUPPORT AVAILABLE
Pre-painting with polyester, superpolyester (HD), PVDF, polyurethane PUR/PA, plastisol, plasticized PVC with thicknesses ranging from 15 mm to 200 mm. Availability on request of other films and non-toxic coatings for occasional contact with food (see page 98).
STANDARD THICKNESS OF POLYURETHANE (S)
Panels from 25 up to 200 (mm). Panels with non-standard thickness are available on request, subject to agreement on minimum quantities. (200 mm thickess panel has a special interlocking joint)
COEFFICIENTE DI DISPERSIONE TERMICA COEFFICIENT OF HEAT LOSS
THICKNESS | TRASMITTANCE EN UNI 14509 | TRASMITTANCE (8 GG / 8 DAYS) |
---|---|---|
(mm) | U = W/m2 K | U = W/m2 K |
30 | 0,70 | 0,64 |
40 | 0,53 | 0,49 |
50 | 0,43 | 0,39 |
60 | 0,36 | 0,33 |
80 | 0,28 | 0,25 |
100 | 0,22 | 0,20 |
120 | 0,18 | 0,16 |
INSIGHTS PIR FOAM
On request is available in PIR foam version (polyisocyanurate), a particular polymeric structure that guarantees excellent characteristics of fire behavior. The entire range of ISOMETAL panels has been certified in Class B-s2, d0 in compliance with UNI EN 13823 (SBI) * where, "B" expresses the quantity of heat produced during the first 600 seconds of the test <7.5 MJ (best value obtainable for foamed products); "S2" represents a very low development of the fumes and "d0" indicates the absolute absence of drops and/or inflamed particles. In last years, the SBI test has become a standard requirement in Europe for fire behavior of building materials. The new European standard for sandwich panels - UNI EN 14509 - uses the SBI system for fire classification purposes. ISOMETAL is the only one in Italy to design light, highly insulating applications with unequaled fire reaction requirements. In many cases it can replace the rock wool panel considering its fire reaction characteristics combined with the very high thermal insulation power.