Afon Casa Novomur Dehumidifying Plaster

NOVOMUR DEHUMIDIFYING PLASTER

Afon Casa Novomur Dehumidifying Plaster

NOVOMUR DEHUMIDIFYING PLASTER  

Innovative thermal insulation smoothing  

A thermal coat with minimum thickness and high energy efficiency

INFORMATION

BRAND  

Afon Casa

PRODUCT TYPE  

Plaster

PRODUCTION  

Made in Italy

FIRE RESISTANCE  

Non Combustible

COMPRESSIVE STRENGTH  

 12 Kg./ cm2 after 30 days

SYSTEM  

Novomur® acts as a moisture flywheel and is something revolutionary in the field of dehumidification systems: it restores water-soaked basements, retaining walls with pressurized water, rooms with saturated air caused by humidity. It makes basements that were no longer used because of their high humidity level liveable once again, it eliminates all types of salt, including that one usually found in stables.

SETTING TIME  

24 hours

DRYING TIME  

5 - 6 days

VAPOUR TRANSMISSION RATE  

370 gr day/m² 2,5 cm thick.

APPARENT SPECIFIC GRAVITY  

150 Kg./ m3

THERMAL CONDUCTIVITY  

λ = 0,045 Kcal/m2 /h/°C (0,055 W/mK)

SOLID CONTENT 

Approximately 475 Kg./ m3

QUALITY  

Then there is a depressurizing effect, due to the fact that a very high quantity of air in contact with the outside air is created in the plaster’s thickness. There is a formation of microvortices, which inhale steam and make the material dry even in the presence of a continuous humidification process. This occurs in the case of walls against the ground or with foundations immersed in water and in the case of widespread water infiltrations.

Afon Casa Novomur Dehumidifying Plaster

STRUCTURE  

Novomur® has an open cell honeycomb structure. Cavities are surrounded by a thermal insulating skeleton which keeps them spaced and protects their internal surfaces. The alveoli communicate with each other through a dense network of micropores which ensure, by suction, the transport of humidity towards the larger alveoli, from which it then evaporates.

THERMAL MASS  

By applying novomur® depressurizing plaster, on both sides of a damp wall, the humidity incorporated throughout the thickness moves, in a continuous flow, towards the hot sides. There it is inhaled and expelled, in the form of vapour, by the depressurizing thermal mass, until completely exhausted. The continuous dehumidification process thus stabilizes at the base of the wall, preventing both humidity and salt formation; in this way the masonry is no longer wetted by dispersed water and much less flaked by salts.

VAPOUR RESISTANCE  

μ = 5.3

ROT PROOFING  

Rot Proof

ENERGY EFFICIENCY

A thermal coating with minimum thickness and high energy efficiency afon casa patented novomur® in 1979. It is the first thermo-depressurizing plaster, capable of dehumidifying masonry subject to any type of humidity, such as that caused by rising damp, on the walls and condensation.