De Nardi Sector 2 Doors
SECTOR 2 DOORS
SECTOR 2 DOORS
The new line of residential sectional doors enriches and completes the wide range of garage closures De Nardi.
It is characterized by an high degree of durability, reliability and versatility; it’s a valid aesthetic alternative to the traditional steel overhead door, thanks to the various solutions, finishes and colors. The tow automation, faster and safer, ensures maximum convenience and ease of use.
INFORMATION
BRAND
Denard
ACOUSTIC ABATEMENT
RW (C;Ctr) = 23 (-2; -3) dB
REACTION TO FIRE
0 - 2
THICKNESS
- 49,5/4,2 : 4,2 cm
- 61,5/4,2 : 4,2 cm
SECTION OF THE MANTLE
The model SECTOR 2 is composed of panels of 49,5 and 61,5 for 4,2 cm of thickness. Composed of two opposing sheets of sendzimir galvanized steel and stucco embossed, wood and smooth; male and female profiled with anti-pinch shape. Inner and outer side with ribs for reinforcement longitudinal channels. Coupling without thermal bridge between internal and external sheet with insulating in polyurethane foam free from cfc injected with the foaming process continuously. With or without internal steel reinforcement.
WEIGHT OF THE PANEL
- 5,56 Kg/m
- 11,12 Kg/m2
- 6,55 Kg/m
- 0,74 Kg/m2
TOLLERANCE
- Spessore " + / -2
- Lunghezza : + / -5
- Passo : + / -2
- Fuori squadra : + / -2
TOTAL K
- 49,5/4,2 : 4,2 cm
- 61,5/4,2 : 4,2 cm
SIZE VERSION IN LIGHT
SIZE
Available in the manual version with architrave of 18 cm for measures up to L. 600 x H. 250 cm. In case of future automation, take an architrave of 23 cm.
TECHNICAL DATA
H MIN | SP | L MAX | H MAX | H MT | H P | G7 MIN | G7 MAX | S | NOTE | |
---|---|---|---|---|---|---|---|---|---|---|
STANDARD | 18 23 | 16,5 21,5 | 600 | 250 - | - 250 | H-G7 | 7,5 | 14 | 9 | 1 |
EXTRA | 15 17 | 22,5 24,5 | 600 | - | 250 300 | H-G7 | 5 | 16,5 | 9 | 1 |
MAXI | 26 | 24,5 | 600 | 350 | 350 | H-G7 | 7,5 | 16,5 | 9 | 1 |
LEGEND
- h min = Minimum architrave height.
- H = Compartment height.
- SP = Distance below guides from the ceiling.
- L = Width height.
- L max = Maximum width of the sectional overhead door.
- H max = Maximum width of the sectional overhead door in manual configuration or ready for motorization.
- H mt = Maximum height of the sectional overhead door.
- H p = Height of passage in the hole level.
- G7 min = Minimal amount of space, in light of the sectional mantle, completely open in the more favorable condition.
- G7 max = Minimal amount of space, in light of the sectional mantle, completely open in the less favorable condition (for example: in configuration with door and glass area).
- S = Minimum dimension of lateral "spalletta".
S tot. = Maximum amount of space of sectional overhead door (sectional width + "spalletta" space)
- Lp = Horizontal guides lenght = H + 50 cm.
CE SAFETY
SICUREZZA CE
1. Parachute against breakage of the cables.
2. Parachute against breakage of the springs.
3. Lower and upper seal for water and wind tightness.
4. Handle and closing lock in manual configuration. Handle and lock for motor release in motorized configuration.
5. Lower oval lifting handle, recessed.
6. CE label identifying the sectional overhead door.
7. Torsion springs made of galvanized steel, dimensioned for 15.000 cycles of operation. To request, springs can be increased.
8. Galvanized and painted steel rails, equipped with vertical seals for water and wind tightness.