Hollaender Structural Glass Railing

STRUCTURAL GLASS RAILING

Hollaender Structural Glass Railing

STRUCTURAL GLASS RAILING

The structural glass railing has an extruded aluminum shoe that is encased with cladding that can be either stainless steel or aluminum. Top caps or rails are available in round and U-channel forms in materials and finishes that match the cladding as well as the assist rail. Wood is a popular option.

INFORMATION

TOP CAP/RAIL MATERIALS

Various available – Round 1.5” OD 304 SS No. 4 brushed finish, Aluminum, Wood.

U CHANNEL MATERIALS

304 SS brushed finish and anodized or powder coated aluminum.

PRODUCTION

Made in United States

MATERIAL

Stainless Steel or Coated Aluminum

CLADDING MATERIALS

Various available — No. 4 304 SS brushed finish, Aluminum .060 in thick, anodized or powder coated.

PERFORMANCE REQUIREMENTS

All railings shall be supplied to conform to applicable secƟons of the following codes:

- InternaƟonal Building Code
- ADAAG

BRAND

Hollaender

PRODUCT TYPE

Railings

GLASS MATERIALS

In order to meet IBC codes, ½” to 3/4” (13/16” overall thickness) in tempered monolithic or laminated, clear/Ɵnted/frosted.

BASE SHOE MATERIALS

6063-T6 Aluminum, 2 ½” wide x 4 1/8” high to hold monolithic or laminated tempered glass, ½” - 13/16” overall width.

GENERAL

Newman by Hollaender® PANELGRIP®2 is a dry glaze system designed for glass infill and balustrade, and is used in all railing applicaƟons that must comply with IBC codes for structural strength and dimensions.

OVERALL DIMENSIONS

-Height of top rail above walking surface: 42”.
-MounƟng : Determined by site condiƟons. Can be top mounted or side mounted to steel, concrete or other substrate that meets loading requirements.

ASSIST RAIL MATERIALS

Various available – 1.5” SS and 1.9” Aluminum.

FEATURES

- Cladding can be stainless steel or coated aluminum
- Glass can be monolithic or laminated, clear or tinted in a variety of shades, ½" to ¾" thick.
- Top rails, caps and assist rails are available in stainless steel, aluminum and wood, in a variety of different shapes and profiles.

STRUCTURAL PERFORMANCE

TOP RAILS OF GUARDS

- Uniform load of 50 lb/Ō. applied in any direcƟon. ∗
- Concentrated load of 200 lb/lf. applied in any direcƟon.
- Uniform and concentrated loads need not be assumed to act concur

INFILL AREA OF GUARDS

Horizontal concentrated load of 200 lb/lf. applied to 1 sq. Ō. at any point on glass infill or other elements composing infill area. Load on infill area need not be assumed to act concurrently with loads on top rails

HANDRAILS

- Uniform load of 50 lb/Ō. applied in any direcƟon.
- Concentrated load of 200 lb/lf. applied in any direcƟon.
- Uniform and concentrated loads need not be assumed to act concur

TEMPERED GLASS

ASTM C1048, Fully Tempered, CondiƟon A, Type 1 (Transparent Flat Glass), Quality Q3. Products shall comply with properƟes indicated for class, thickness, and manufacturing process that have been tested for surface and edge compression according to ASTM C1048 and for impact strength according to 16 CFR 1201 for Category 2 materials.