Gorter Hatches Rhtei Fire-resistant Roof Hatch

RHTEI FIRE-RESISTANT ROOF HATCH

Gorter Hatches Rhtei Fire-resistant Roof Hatch

RHTEI FIRE-RESISTANT ROOF HATCH 

The fire-resistant roof hatch offers practical and safe access to flat roofs and at the same time, in closed state, ensures a fire-resistant seal of the space below. Fire protection of 120 minutes is offered. The fire-resistant roof hatches can be used for flat roofs with a maximum slope of 5°.

features 

SAFE ONE-HANDED OPERATION

All fire-resistant roof hatches have easy opening features with a counterbalance system and fallback inhibitor. With these features, the roof hatch can always be opened with minimum effort using one hand. To close the cover, the release can also be operated with one hand.
Another safety feature of the roof hatch is Gorter’s characteristic yellow handle. This offers a safe grip when climbing up to and down from the roof.

Gorter Hatches Rhtei Fire-resistant Roof Hatch

CLASSIFICATION- FIRE STANDARDS EXPLAINED

The two important parameters for roof hatches are the integrity and thermal insulation. This is not the same as the heat insulation parameter (Rc or Uw) which indicates the heat resistance of the construction. By the way, this is also very high for the fire-resistant roof hatch, with fully thermally insulated construction.

Gorter Hatches Rhtei Fire-resistant Roof Hatch

THERMAL INSULATION: I.

This indicates for how long (in minutes) a separating element prevents the penetration of heat in case of a fire. As a result, the unexposed side cannot ignite and any combustible element in the immediate vicinity of this side cannot ignite either.

INTEGRITY: E.

Indicates how long (in minutes) a separating element, exposed to a fire on one side, prevents flames or hot gases from penetrating to the unexposed side.

Gorter Hatches Rhtei Fire-resistant Roof Hatch

COMBINATION WITH GORTER CLIMBING EQUIPMENT 

The fire-resistant roof hatch can be combined with a Gorter ladder, scissor stair or fixed stair. This ensures a complete and very safe roof access solution. The roof hatch and climbing equipment are fully coordinated in terms of design. Additionally, the combinations are TÜV NORD-certified, and you can cover your RIE with the included documents.

information 

BRAND

Gorter

PRODUCTION

Made in Australia

PROOF

Burglar- and sound-proof

SAFE

Safe to operate with one hand

THERMALLY 

Thermally separated and insulated steel construction

CERTIFICATIONS

Fire class EW-120 and smoke tightness R-180 (KOMO:SKG.0372.0488)

FIRE

Fire class according to EN1634-1, EN13501-2, AS1530-4 and BS476:part22

SIZE

In standard and special sizes

USE

Sub-floor access and fire seal to room above

COATED

Powder-coated in RAL7011 (outside) and RAL9010 (inside)

LOCK

Cylinder lock, inside operation. With 3 point lock from hinge side > 1400 mm.

CHARACTERISTICS

Fire Rated, Safe To Operate With One Hand, Automatic Locking In Open Position

STANDARD VERIONS 

The fire-resistant roof hatch is available in 7 standard sizes and special sizes up to 1000 x 2000 mm.

FULLY THERMALLY BROKEN 

The fully thermally isolated curb and cover have a high insulation value and so minimise the chance of unwanted condensation forming while also saving energy costs.

WARRANTY

10-year warranty on the roof hatch

DIMENSIONS

Dimensions > 1,400 mm with 3-point locking mechanism

Gorter Hatches Rhtei Fire-resistant Roof Hatch

GORTER® - COMPLETELY ASSEMBLED WITH:

- Intumescent tape
- Weather tight gasket
- Thermal separated and insulated steel construction
- Diagonal handle to safely enter and leave roof hatch
- Counter balancing system for controlled opening and closing
- Hold-open arm that engages automatically, one hand release
- Cylinder lock, inside operation. With 3 point lock from hinge side > 1399 mm.

FIRE-RESISTANT FOR 120 MINUTES

The Gorter RHTEI roof hatch is the only one tested according to EN 1634-1 and EN 13501-2 by test institute Efectis. The roof hatch also complies with the Australian standard AS1530-4 and the British standard BS476:PART22.
The roof hatch meets the following specifications:
- EI 1: 120 minutes
- EI 2: 120 minutes
- E: 120 minutes

DETAILS

The Gorter fire-resistant steel roof hatch provides practical and safe access to flat roofs and at the same time, when closed, provides a fire-resistant seal for the space below. Roof hatches can be installed on flat roofs with a maximum slope of 5°.

PERFORMANCE

- Sound reduction (EN-ISO 717-1:2013): 25 dB
- Wind and water tightness (EN 12208): Class E 650
- Construction strength (EN1026/EN1027): ± 3000 Pa
- Resistance to wind load (EN 12210): Class E 3000
- Air tightness (EN 1026): 0.5 m3/hm1
- Resistance to snow loads (EN 1991-1-3):3,97kN/m²
- Impact hard body (EN 356): Class P5A
- Impact soft body (EN 13049): Class 5

STANDARD DIMENSIONS / WEIGHT

- RHTEI7090: 700 x 900 mm / 134 kg
- RHTEI9090: 900 x 900 mm / 157 kg
- RHTEI7014: 700 x 1400 mm / 185 kg
- RHTEI1010: 1000 x 1000 mm / 180 kg
- RHTEI1015: 1000 x 1500 mm / 236 kg
- RHTEI1020: 1000 x 2000 mm / 298 kg
- RHTEI9024: 900 x 2400 mm / 323 kg

INSTAGRAM