Stacbond Fr Panels
STACBOND FR PANELS
STACBOND FR PANELS
Stacbond® FR panels are composed of two aluminum sheets and an inner fire retardant core of thermoplastic resins with mineral charge.
The panels have excellent mechanical properties such as: great rigidity, excellent flatness and impact resistance. They comply with the majority of requirements for fire-resistance classification
INFORMATION
BRAND
Stacbond®
NFPA 285
PASS
UNE EN 13501-1:2007
B-s1, d0
PN-90/8-02867
NRO
THICKNESS OF LACQUERED SHEET
0.50mm
WIDTH (MIN. / MAX.)
800 / 2000mm
LENGH (MIN. / MAX.)
2000 / 6000mm
CAN/ULC-S102-18
CLASS A: SD: 0; FS: 0
ASTM E84
CLASS A: SD 5; FS: 0
CAN/ ULC-S134
PASS
DOWNLOAD
↓ Information Sheet
PROOF STRESS (RP 0.2)
- ≥ 80N/mm2
- ≥ 110N/mm2
TENSILE STRENGHT (Rm)
- 125≥ Rm≥ 185N/mm2
- 130 ≥ Rm≥ 215N/mm2
CHARACTERISTICS
-High Rigidity -Excellent Flatness -Impact Resistance -Durability -Ease Of Maintenance -Recyclable -Uv-resistance -Dimensional Stability
RIGIDITY (EI)
- 2610kNcm2/m
- DIN 53293
TOTAL THICKNESS
4 mm
DENSITY
1.70 ± 0.10g/cm3
SOUND REDUCTION (RW)
- 33.30 ± 1.30db
- ISO 717-1:2013
CANADA
- PASS
- CAN/ULC-S134
HIDDEN FACE
- 3005/3105
- UNE EN 573-3
PANEL WEIGHT
7.70 ± 0.50kg/m2
THICKNESS TOLERANCE
-0.15 / +0.10mm
WIDTH TOLERANCE
-0 / +2mm
LENGHT TOLERANCE
-0 / +10mm
ELONGATION (A50)
- ≥ 3%
- ≥ 4%
DENSITY (Ρ)
- 2700kg/m3
- 2700kg/EN 485-2
HUNGARY
- PASS
- MSZ 14800-6
THERMAL CONDUCTIVITY (Λ)
- 5.67W/mºC
- UNE-EN ISO 12567-1
USE
Ventilated Facades
EUROPE
- USGBC
- LEED2014
MODULUS OF ELASTICITY (E)
70 000N/mm2
PEELING
- ≥ 9,80N/mm
- ASTM D903 - 98 (2004)
USA
- ASTM E84
- CLASS A: SD: 10; FS: 0
- CLASS A: SD: 5; FS: 0
ACOUSTIC INSULATION RW (C;CTR)
- 33 (-1; -4)db
- ISO 717-1:2013
HIDDEN FACE ALUMINIUM ALLOY
- UNE EN 573-3
- 3005 / 3105
SQUARENESS
± 3mm(Diagonal Tolerance)
COUNTRY
-Norm -Organism
THERMAL RESISTANCE (R)
- 0.014m2K/W
- UNE-EN ISO 12567-1
POLONIA
- NRO
- NRO
- PN-90/8-02867
UE
-EN 13501-1
- A2-s1, d0
- B-s1, d0
OPERATING TEMPERATURE
-50 / + 80ºC
FIRE REACTION
- B - S1, d0
- UNE-EN-13501-1:2007
PROTECTIVE FILM WIDTH
0; -5mm(Tolerance)
VISIBLE FACE ALUMINIUM ALLOY
-UNE EN 573-3 -5005
CANADA
- CLASS A: SD: 0 FS: 0
- CAN/ULC-S102-18
INTERNATIONAL
- Tecnalia R & Guipúzcoa
- EPDS-P-01289
APPLICATIONS
- External
- New Build
- Renovation
USA
- NFPA 285
- PASS
- PASS
RESISTANT MODULE (W)
-1.40cm3/m -DIN 53293
THERMAL EXPANSION (Α)
- 2.36mm/m (100º)