Industry Sika Anchorfix®-3030
SIKA ANCHORFIX®-3030
INFORMATION
TENSILE STRENGTH IN FLEXURE
~45 N/mm2 (7 days, +20 °C) : (ASTM D 790)
TENSILE STRENGTH
~23 N/mm2 (7 days, +20 °C) : (ASTM D 638)
COLORS
- Part A : Off white
- Part B : Grey
- A+B mixed : Light grey
STRUCTURAL WORK
- Rebar / steel reinforcement anchoring in new and refurbishment works
- Threaded rods
- Bolts and special fastening / fixing systems
COMPRESSIVE STRENGTH
~95 N/mm2 (7 days, +20 °C) : (ASTM D 695)
SHELF LIFE
24 months from date of production
SUSTAINABILITY
Conformity with LEED v2009 IEQc 4.1: Low-Emitting Materials - Adhesives and Sealants, Report No. G23807C_04
SERVICE TEMPERATURE
- Long term : -40 °C min. / +50 °C max.
- Short term (1–2 hours) : +70 °C
METALWORK, CARPENTRY
- Railings
- Window and door frames
- Handrails, balustrades and supports
STORAGE CONDITIONS
The product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +10 °C and +25 °C. Always refer to packaging.
COMPOSITION
Epoxy resin
DENSITY
A+B mixed : ~1.5 kg/l
SYSTEM STRUCTURE
Ancillary products:
- Sika AnchorFix® Cleaning Pump
- Sika AnchorFix® Flexible Extensions
- Sika AnchorFix® Hole Cleaning Brushes Hybrid
- Sika AnchorFix® Hole Cleaning Brushes Steel
- Sika AnchorFix® Static Mixers -Nozzles
- Sika AnchorFix® Straight Extensions
- Sika AnchorFix® Perforated Sleeves
SUBSTRATES
- Wood
- Solid rock
- Hollow and solid masonry
- Natural and reconstituted stone
- Concrete (cracked and un-cracked)
APPROVALS / CERTIFICATES
-CE Marking and Declaration of Performance to ETAG 001 Part 1 - Anchors in general and Part 5 - Bonded anchors, used as European Assessment Document (EAD) -CE Marking and Declaration of Performance to ETA 17/0694 - Bonded injection type anchor for use in cracked and uncracked concrete
- Fire Evaluation of Post Installed Rebar Connections CEN EN 1991-1-2, Sika AnchorFix®-3030, CSTB, Test report MRF 26072904/C
ADVANTAGES
- Long open Time
- Low emissions
- Low wastage
- Can be used in damp concrete
- ETA for post installed rebar connections
- Seismic tested (C1 & C2)
- Suitable for contact with drinking water
- Fire resistant
- Styrene-free
- High load capacity
- Good adhesion to substrate
- Shrinkage-free hardening
- ETA for anchoring in cracked concrete
- Standard sealant guns can be used (300ml cartridge)
APPLICATION INFORMATION
-Mixing ratio : Part A : Part B = 3 : 1 by volume
-Layer thickness : ~8 mm max
-Sag flow : Non-sag, including overhead
-Product temperature : +10 °C min. / +40 °C max.
-Ambient air temperature : +5 °C min. / +40 °C max.
-Substrate temperature : +5 °C min. / +40 °C max.
-Dew point : Beware of condensation. Substrate temperature during application must be at least +3 °C above dew point.
APPLICATION STEPS
SUBSTRATE QUALITY
- Mortar and concrete must be at the required design strength.
- Substrate tensile / compressive strengths (concrete, masonry, natural stone) must be confirmed by testing.
- The anchor hole must always be clean, dry, free from oil and grease etc.
- Loose particles must be removed from the holes.
- Threaded rods and rebar's must be cleaned thoroughly and free from dirt, oil, grease, corrosion products or any other - substances and particles which could affect adhesion.