Technowood Siding Façade System
TW SIDING SYSTEMS
TW SIDING SYSTEMS
The world’s first A2 fireproof class natural wood coated material Technowood has become the new aesthetic image of the building sides. This light system which easily passes the side openings requested by the architects does not bring load to the building as well as it provides advantage with fast production, labor and cost.
Technowood, which is consistent of a great combination of naturalness, tissue and feel of wood at one side and speed, durability, lightness and recycling brought by the technology at the other side, prevents situations such as expansion, rotation, cracking, mildew, fungi, bacteria formation, frequent maintenance and varnishing that ate disadvantages of massive wood as well as it provides added value to the forests and environmental awareness by using 98% less wood.
INFORMATION
BRAND
Technowood
PRODUCTION
Made in Turkey
GUARANTEE
20 years
SIZES
Length up to 7.5 mts.
APPLICATIONS
- Façade systems
- Wall and Ceiling Cladding
FIELD OF USE
- Wall
- Door
- Garage Door
- Ceiling Coating
PRODUCT
- GRP
- Aluminum
USE
- Construction
- Decoration Material
CHARACTERISTICS
- A2 Class Fireproof
- Weights 2.71 Gr/cm3
- Recyclable Material
- Can Be Assembled
- No Screws Or Similar Fittings Visible From The Outside
FEATURES
A2 class fireproof alu, light, standard 6 mt or 10 15 16 up to 7.5 meters or 20 cm of width
SYSTEM
Assembled by being screwed on carcass system with T profile and L brackets after beıng taken to the scale on vertıcal or horızontal layers
ALUMINUM MATERIAL SPECIFICATIONS
COEFFICIENTS | VALUE | UNIT |
---|---|---|
Specific Weight | 2.71 | GR/CM^3 |
Expansion Factor | 23,4x0,000001 | 1/C |
Elasticity Module | 6900 | G /MM^2 |
Pulling Strength | 17.5 | 24C DEKG /MM^2 |
Elongation | % 08 | 24C DEKG /MM^2 |
Hardness | 60-65 | BRINELL(HB)KG /MM^2 |
Yield Strength | 14 | KG /MM^2 |
Shear Strength | 13 | KG /MM^2 |
Aluminium Alloy | AIMgSi0,5 /6063/ 60 | DIN -GERMANY/BS-ENGLAND/ETIAL-TURKEY |
REACTION TO FIRE
COEFFICIENTS | VALUE | UNIT |
---|---|---|
Reaction to Fire | EN 13501-1:2007+A1:2009 | A2 Class |
Smoke Production | EN 13501-1:2007+A1:2009 | S1 |
Flaming Droplets/Particles | EN 13501-1:2007+A1:2009 | d0 |
Limited-combustibility | NFPA 259 | Passed |
Surface Burning Characteristics | UL723/NFPA 255/ASTM E84 | ClassA |
Flammability | GOST30244-94 | Non-combustible |
Fire Hazard Properties | AS5637.1:201 | Group 1 Rating |
Spread of Flame | AS/NZ 1530.3-1999 | Index-0 |
CHEMICAL AND BIOLOGICAL FEATURES
COEFFICIENTS | VALUE | UNIT |
---|---|---|
Formaldehyde Emission | EN 717-2:1994 | 0,1mgHCHO/(m2h) |
Heavy Metal Content (Pb,Ge,Cr,Hg) | GB18584-2001/GB18580 -2001 | <0,5ppm |
Evaluation of the action ofmicroorganisms (scalefrom 0 to5) | EN ISO 846:97 | Test Result : 1 |