Unilin Insulation UK Ltd.

Xtratherm SR/RS Insulation for Ventilated Rainscreen Cladding

SR/RS INSULATION

SR/RS

Insulation for Ventilated Rainscreen Cladding

SR/RS Rainscreen Board provides ultimate thermal performances in rainscreen applications. Safe-R is a superior performance phenolic insulation with a Euroclass B fire classification.

Xtratherm SR/RS Insulation for Ventilated Rainscreen Cladding
Xtratherm SR/RS Insulation for Ventilated Rainscreen Cladding

It is faced with low emissivity foil facings on both sides and has a Lambda value as Low as 0.020 W/mK. SR/RS has been tested to BS 8414 (Parts 1 and 2) in a number of compliant system specifications. For comprehensive guidance and copies of reports contact technical support.

For compliance with the latest Building Regulations and Standards in other jurisdictions, consult your system supplier and local building control authorities.

Xtratherm SR/RS Insulation for Ventilated Rainscreen Cladding

Xtratherm SR/RS is not suitable for use on high-rise buildings in England where; the building contains one or more dwellings, an institution or a room for residential purposes (excluding any room in a hostel, hotel or boarding house), student accommodation, care homes, sheltered housing, hospitals and dormitories in boarding schools, with a storey at least 18m above ground.

INFORMATION

THERMAL PERFORMANCE

Rainscreen façade systems are bespoke and configuration and specification of those systems are specific to individual buildings. System supports and fixings will have an effect on the thermal performance of that system. Thermal performances and patterns of fixings should be sought from the system manufacturer or supplier. Advice given in BR443 'Conventions for U-Value Calculation' should be followed.

KEY POINT

- Superior Performance Phenolic Insulation
- Euroclass B -s1 d0 Fire Classification
- Lower Lambda values for improved U-Values
- Tested and Approved under BS 8414
- Meets criteria of BR135

Xtratherm SR/RS Insulation for Ventilated Rainscreen Cladding

SPECIFICATION CLAUSE

The rainscreen insulation shall be Xtratherm Safe-R SR/RS _ _ _mm manufactured to EN 13166 by Xtratherm, comprising a rigid Phenolic core between low emissivity foil facings. The SR/RS ___mm with Agrément declared Lambda value as low as 0.020 W/mK to achieve a U-Value of ___W/m2K for the wall element. To be installed in accordance with instructions issued by Xtratherm.

THERMAL RESISTANCES

THICKNESS (MM)R-VALUE (M2 K/W)
502.35
602.85
753.55
803.80
1005.00
1206.00

TECHNICAL ASSESSMENTS

In specifications where no large scale test data is available a Technical Assessment undertaken by a suitably qualified person, normally UKAS approved, and based upon actual test data, can be used to demonstrate compliance with BR135. Xtratherm have a number of technical assessments completed by UKAS approved bodies. For further information or copies of assessments, contact the Xtratherm Technical Team.

Unilin Insulation UK Ltd.
T +44 371 2221033 F +44 371 2221044
Unilin Insulation UK Ltd.
Park Rd, Holmewood, Chesterfield S42 5UY, United Kingdom