A. Proctor Group Ltd

Proctor Group Reflectatherm Plus Roll

REFLECTATHERM PLUS ROLL

Proctor Group Reflectatherm Plus Roll

REFLECTATHERM PLUS ROLL

With an R-Value of 0.78 m2K/W, Reflectatherm Plus is the industry leading reflective vapour barrier. 

It combines the highest thermal performance in its class with a high vapour resistance to prevent interstitial condensation.

Suitable for use in walls, ceilings and floors on the warm side of the insulation. Reflectatherm Plus is a reflective, high resistance vapour barrier for internal walls, ceilings and floors, specifically designed to enhance the thermal performance when placed on the warm side of the insulation.

The membrane should be installed with the foil side facing the cavity. In ceilings the product is placed between the underside of the rafters and the ceiling lining.

Adjacent sheets should be lapped by at least 50mm and sealed with a suitable tape. Minimise penetrations caused by services and seal all joints.

INFORMATION

ROLL SIZE

- 1.5m x 50m, 2.7m or 3m x 100m

MATERIAL

- Polypropylene Spunbond Nonwoven,
- Polyethylene and Foil laminate

MASS PER UNIT AREA

150 g/m2

REACTION TO FIRE

Class E

WATER VAPOUR RESISTANCE SD

150 m

WATER PENETRATION

Class W1 (Before and After ageing)

EMISSIVITY

0.04

VAPOUR RESISTANCE

750 MN/sg

FLEXIBILITY AT LOW TEMPERATURE

No cracking at temperature minus 40°C

TENSILE STRENGTH

- MD 255N/50mm
- CD 200N/50mm

ELONGATION

- MD 59%
- CD 70%

BENEFITS

- R value of 0.78 m2 K/W when used with a minimum 19mm service cavity. 
- High vapour resistance. 
- Improved airtightness.
- Creates service void.
- Creates an unbroken vapour control layer.
- Sd Value of 150m.
- Vapour Resistance 750 MNs/g.
- Help meets the requirements of the Part L in England and Wales, Section 6 in Scotland.

TECHNICAL PROPERTIES

- Mass per unit area: to be no less than 150g/m² c
- Water vapour resistance: to be no greater than Sd = 150m when tested to EN1931
- Reaction to Fire: to be no worse than Class E when tested to EN 11925-2 
- Water Penetration: to be no less than Class W1, aged and unaged, when tested to EN 1928
- Tensile Strength: to be no less than MD 255N/50mm; CD 200N/50mm when tested to EN 12311-2 
- Tear Resistance: to be no less than MD 164N; CD 157 N when tested to EN 12310-1 
- Elongation: to be no less than MD 59%; CD 70% when tested to EN 12311-1

DOWNLOAD

Proctor Group Reflectatherm Plus Roll
Date Sheet - Reflectatherm Plus
Proctor Group Reflectatherm Plus Roll
Product Solutions for
Housebuilders & Developers
Proctor Group Reflectatherm Plus Roll
Performance Specification - Reflectatherm Plus
Proctor Group Reflectatherm Plus Roll
User Guide
Proctor Group Reflectatherm Plus Roll
Installation Guide
Proctor Group Reflectatherm Plus Roll
Certificate
Proctor Group Reflectatherm Plus Roll
CAD

A. Proctor Group Ltd
T +44 1250 872261 F +44 1250 872727
A. Proctor Group Ltd
The Haugh, Ashgrove Rd, Blairgowrie PH10 7ER, United Kingdom